{"product_id":"cj12-22-12v-22ah-sealed-lead-acid-battery-high-rate-vrla-agm-battery-for-ups-fire-panels-security-emergency-lighting","title":"CJ12-22 12V 22Ah Sealed Lead Acid Battery | High Rate VRLA AGM Battery for UPS, Fire Panels, Security \u0026 Emergency Lighting","description":"\u003cp data-start=\"402\" data-end=\"878\"\u003eThe \u003cstrong data-start=\"406\" data-end=\"451\"\u003eCJ12-22 12V 22Ah sealed lead acid battery\u003c\/strong\u003e is a high-rate \u003cstrong data-start=\"467\" data-end=\"500\"\u003eVRLA AGM rechargeable battery\u003c\/strong\u003e designed for reliable standby and backup power in demanding applications such as \u003cstrong data-start=\"582\" data-end=\"686\"\u003eUPS systems, fire alarm panels, emergency lighting, security systems and electrical backup equipment\u003c\/strong\u003e. With a \u003cstrong data-start=\"695\" data-end=\"726\"\u003e5-year floating design life\u003c\/strong\u003e, strong grid construction and high-current discharge capability, the CJ12-22 is built to deliver stable performance when power continuity matters most.\u003c\/p\u003e\n\u003cp data-start=\"880\" data-end=\"1229\"\u003eEngineered for high-rate load discharge applications, the CJ12-22 uses a robust plate design and specialised paste formulation to support strong output during short-duration, high-current demand. Its sealed valve-regulated lead acid construction makes it suitable for maintenance-free operation in commercial, industrial and critical backup systems.\u003c\/p\u003e\n\u003cp data-start=\"1231\" data-end=\"1554\"\u003eThis battery features a compact footprint of \u003cstrong data-start=\"1276\" data-end=\"1300\"\u003e181mm x 77mm x 167mm\u003c\/strong\u003e, approximate weight of \u003cstrong data-start=\"1324\" data-end=\"1333\"\u003e5.9kg\u003c\/strong\u003e, and \u003cstrong data-start=\"1339\" data-end=\"1366\"\u003eFaston F3\/F13 terminals\u003c\/strong\u003e for secure electrical connection. The CJ12-22 is commonly listed for use in security equipment, emergency lighting, fire panels and UPS applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"xmyzu0\" data-start=\"1556\" data-end=\"1564\"\u003eSKU\u003c\/h2\u003e\n\u003cp data-start=\"1565\" data-end=\"1576\"\u003e\u003cstrong data-start=\"1565\" data-end=\"1576\"\u003eCJ12-22\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"143b91f\" data-start=\"1578\" data-end=\"1595\"\u003eProduct Code\u003c\/h2\u003e\n\u003cp data-start=\"1596\" data-end=\"1607\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1607\"\u003eCJ12-22\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1trkvdi\" data-start=\"1609\" data-end=\"1640\"\u003eWhat’s Included in the Box\u003c\/h2\u003e\n\u003cp data-start=\"1641\" data-end=\"1690\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1690\"\u003e1 x CJ12-22 12V 22Ah Sealed Lead Acid Battery\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"18p0o4p\" data-start=\"1692\" data-end=\"1710\"\u003eMain Features\u003c\/h2\u003e\n\u003cul data-start=\"1711\" data-end=\"2402\"\u003e\n\u003cli data-section-id=\"5whbpe\" data-start=\"1711\" data-end=\"1776\"\u003e\n\u003cstrong data-start=\"1713\" data-end=\"1734\"\u003e12V 22Ah capacity\u003c\/strong\u003e for dependable standby and backup power\u003c\/li\u003e\n\u003cli data-section-id=\"1ko2uhs\" data-start=\"1777\" data-end=\"1851\"\u003e\n\u003cstrong data-start=\"1779\" data-end=\"1816\"\u003eHigh-rate VRLA AGM battery design\u003c\/strong\u003e for strong discharge performance\u003c\/li\u003e\n\u003cli data-section-id=\"1684xch\" data-start=\"1852\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1854\" data-end=\"1902\"\u003e83.5W @ 15-minute rate to 1.67V\/cell at 25°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"g7gqnf\" data-start=\"1905\" data-end=\"1958\"\u003e\u003cstrong data-start=\"1907\" data-end=\"1956\"\u003eMaximum discharge current: 220A for 5 seconds\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ilk48h\" data-start=\"1959\" data-end=\"2031\"\u003e\n\u003cstrong data-start=\"1961\" data-end=\"1992\"\u003e5-year floating design life\u003c\/strong\u003e under recommended standby conditions\u003c\/li\u003e\n\u003cli data-section-id=\"17gcg19\" data-start=\"2032\" data-end=\"2114\"\u003e\n\u003cstrong data-start=\"2034\" data-end=\"2081\"\u003eSealed, rechargeable lead acid construction\u003c\/strong\u003e for maintenance-free operation\u003c\/li\u003e\n\u003cli data-section-id=\"1lli7vj\" data-start=\"2115\" data-end=\"2172\"\u003e\n\u003cstrong data-start=\"2117\" data-end=\"2144\"\u003eFaston F3\/F13 terminals\u003c\/strong\u003e for reliable installation\u003c\/li\u003e\n\u003cli data-section-id=\"13exzfv\" data-start=\"2173\" data-end=\"2262\"\u003e\n\u003cstrong data-start=\"2175\" data-end=\"2201\"\u003eABS container material\u003c\/strong\u003e with UL94-HB rating; UL94-V2 option available upon request\u003c\/li\u003e\n\u003cli data-section-id=\"60jk4m\" data-start=\"2263\" data-end=\"2402\"\u003eSuitable for \u003cstrong data-start=\"2278\" data-end=\"2364\"\u003eUPS, fire panels, emergency lighting, security equipment and standby power systems\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"wkg1n\" data-start=\"2404\" data-end=\"2432\"\u003eDetailed Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2434\" data-end=\"3539\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2434\" data-end=\"2461\"\u003e\n\u003ctr data-start=\"2434\" data-end=\"2461\"\u003e\n\u003cth data-start=\"2434\" data-end=\"2450\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2450\" data-end=\"2461\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2472\" data-end=\"3539\"\u003e\n\u003ctr data-start=\"2472\" data-end=\"2498\"\u003e\n\u003ctd data-start=\"2472\" data-end=\"2487\" data-col-size=\"sm\"\u003eProduct Code\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2487\" data-end=\"2498\"\u003eCJ12-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2499\" data-end=\"2553\"\u003e\n\u003ctd data-start=\"2499\" data-end=\"2514\" data-col-size=\"sm\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2514\" data-end=\"2553\"\u003eSealed Lead Acid \/ VRLA AGM Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2554\" data-end=\"2579\"\u003e\n\u003ctd data-start=\"2554\" data-end=\"2572\" data-col-size=\"sm\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2572\" data-end=\"2579\"\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2580\" data-end=\"2602\"\u003e\n\u003ctd data-start=\"2580\" data-end=\"2597\" data-col-size=\"sm\"\u003eCells Per Unit\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2597\" data-end=\"2602\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2603\" data-end=\"2633\"\u003e\n\u003ctd data-start=\"2603\" data-end=\"2614\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"2614\" data-end=\"2633\" data-col-size=\"md\"\u003e12V 22Ah \/ 20HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2634\" data-end=\"2700\"\u003e\n\u003ctd data-start=\"2634\" data-end=\"2653\" data-col-size=\"sm\"\u003eHigh Rate Output\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2653\" data-end=\"2700\"\u003e83.5W @ 15-minute rate to 1.67V\/cell @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2701\" data-end=\"2727\"\u003e\n\u003ctd data-start=\"2701\" data-end=\"2718\" data-col-size=\"sm\"\u003eApprox. Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2718\" data-end=\"2727\"\u003e5.9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2728\" data-end=\"2775\"\u003e\n\u003ctd data-start=\"2728\" data-end=\"2756\" data-col-size=\"sm\"\u003eMaximum Discharge Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2756\" data-end=\"2775\"\u003e220A, 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2776\" data-end=\"2814\"\u003e\n\u003ctd data-start=\"2776\" data-end=\"2798\" data-col-size=\"sm\"\u003eInternal Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2798\" data-end=\"2814\"\u003eApprox. 12mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2815\" data-end=\"2860\"\u003e\n\u003ctd data-start=\"2815\" data-end=\"2846\" data-col-size=\"sm\"\u003eNormal Operating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2846\" data-end=\"2860\"\u003e25°C ± 5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2861\" data-end=\"2908\"\u003e\n\u003ctd data-start=\"2861\" data-end=\"2891\" data-col-size=\"sm\"\u003eDischarge Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2891\" data-end=\"2908\"\u003e-20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2909\" data-end=\"2951\"\u003e\n\u003ctd data-start=\"2909\" data-end=\"2936\" data-col-size=\"sm\"\u003eCharge Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2936\" data-end=\"2951\"\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2952\" data-end=\"2997\"\u003e\n\u003ctd data-start=\"2952\" data-end=\"2980\" data-col-size=\"sm\"\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2980\" data-end=\"2997\"\u003e-20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2998\" data-end=\"3065\"\u003e\n\u003ctd data-start=\"2998\" data-end=\"3023\" data-col-size=\"sm\"\u003eFloat Charging Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3023\" data-end=\"3065\"\u003e13.7V to 13.9V DC\/unit average at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3066\" data-end=\"3147\"\u003e\n\u003ctd data-start=\"3066\" data-end=\"3105\" data-col-size=\"sm\"\u003eEqualisation \/ Cycle Service Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3105\" data-end=\"3147\"\u003e14.6V to 14.8V DC\/unit average at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3148\" data-end=\"3195\"\u003e\n\u003ctd data-start=\"3148\" data-end=\"3187\" data-col-size=\"sm\"\u003eRecommended Maximum Charging Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3187\" data-end=\"3195\"\u003e6.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3196\" data-end=\"3247\"\u003e\n\u003ctd data-start=\"3196\" data-end=\"3213\" data-col-size=\"sm\"\u003eSelf Discharge\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3213\" data-end=\"3247\"\u003eLess than 3% per month at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3248\" data-end=\"3285\"\u003e\n\u003ctd data-start=\"3248\" data-end=\"3264\" data-col-size=\"sm\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3264\" data-end=\"3285\"\u003eFaston tab F3\/F13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3286\" data-end=\"3354\"\u003e\n\u003ctd data-start=\"3286\" data-end=\"3307\" data-col-size=\"sm\"\u003eContainer Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3307\" data-end=\"3354\"\u003eABS UL94-HB; UL94-V2 available upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3355\" data-end=\"3398\"\u003e\n\u003ctd data-start=\"3355\" data-end=\"3368\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"3368\" data-end=\"3398\" data-col-size=\"md\"\u003e181mm L x 77mm W x 167mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3399\" data-end=\"3445\"\u003e\n\u003ctd data-start=\"3399\" data-end=\"3413\" data-col-size=\"sm\"\u003eDesign Life\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3413\" data-end=\"3445\"\u003e5 years floating design life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3446\" data-end=\"3539\"\u003e\n\u003ctd data-start=\"3446\" data-end=\"3489\" data-col-size=\"sm\"\u003eCertification \/ Quality System Mentioned\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3489\" data-end=\"3539\"\u003eISO9001 listed on supplied specification sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"hubk8\" data-start=\"3541\" data-end=\"3569\"\u003ePractical Use Scenarios\u003c\/h2\u003e\n\u003cp data-start=\"3570\" data-end=\"3670\"\u003eThe \u003cstrong data-start=\"3574\" data-end=\"3585\"\u003eCJ12-22\u003c\/strong\u003e is suitable for applications requiring stable rechargeable standby power, including:\u003c\/p\u003e\n\u003cul data-start=\"3672\" data-end=\"3992\"\u003e\n\u003cli data-section-id=\"1hfrbrl\" data-start=\"3672\" data-end=\"3721\"\u003eFire alarm and fire protection control panels\u003c\/li\u003e\n\u003cli data-section-id=\"1qpg1d3\" data-start=\"3722\" data-end=\"3759\"\u003eEmergency lighting backup systems\u003c\/li\u003e\n\u003cli data-section-id=\"tzck3d\" data-start=\"3760\" data-end=\"3815\"\u003eSecurity alarm systems and access control equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1pfp1g9\" data-start=\"3816\" data-end=\"3844\"\u003eUPS backup power systems\u003c\/li\u003e\n\u003cli data-section-id=\"1t5clr9\" data-start=\"3845\" data-end=\"3871\"\u003eStandby power cabinets\u003c\/li\u003e\n\u003cli data-section-id=\"1unbh3f\" data-start=\"3872\" data-end=\"3925\"\u003eTelecommunications and low-voltage backup systems\u003c\/li\u003e\n\u003cli data-section-id=\"q9yexm\" data-start=\"3926\" data-end=\"3992\"\u003eElectrical equipment requiring a compact 12V 22Ah VRLA battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"178j2km\" data-start=\"3994\" data-end=\"4023\"\u003eCharging \u0026amp; Storage Notes\u003c\/h2\u003e\n\u003cp data-start=\"4024\" data-end=\"4266\"\u003eFor standby use, the recommended float charge voltage is \u003cstrong data-start=\"4081\" data-end=\"4116\"\u003e13.7V to 13.9V per unit at 25°C\u003c\/strong\u003e. For cycle or equalisation use, the recommended voltage is \u003cstrong data-start=\"4176\" data-end=\"4211\"\u003e14.6V to 14.8V per unit at 25°C\u003c\/strong\u003e. The recommended maximum charging current is \u003cstrong data-start=\"4257\" data-end=\"4265\"\u003e6.0A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4268\" data-end=\"4538\"\u003eVRLA batteries may be stored for more than 6 months at 25°C, with a self-discharge rate below 3% per month at 25°C. Batteries should be recharged before use after storage, and the supplied guidelines recommend charging at least once every six months when stored at 25°C.\u003c\/p\u003e\n\u003ch2 data-section-id=\"iijgyl\" data-start=\"4540\" data-end=\"4565\"\u003eWarranty Information\u003c\/h2\u003e\n\u003cp data-start=\"4566\" data-end=\"4927\"\u003e1-year Warranty \u003c\/p\u003e\n\u003ch2 data-section-id=\"136guew\" data-start=\"4929\" data-end=\"4951\"\u003eBrand Description\u003c\/h2\u003e\n\u003cp data-start=\"4952\" data-end=\"5289\"\u003eOlympic Batteries Pty Ltd is an Australian battery supplier. The CJ12-22 is a 12V 22Ah sealed lead acid battery suitable for general-purpose applications including security equipment, emergency lighting, fire panels and UPS systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"lurbuw\" data-start=\"5291\" data-end=\"5331\"\u003eDatasheets \u0026amp; Downloadable Resources\u003c\/h2\u003e\n\u003cul data-start=\"5332\" data-end=\"5538\"\u003e\n\u003cli data-section-id=\"125w5kz\" data-start=\"5332\" data-end=\"5363\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/BAT4067_CJ12-22_datasheet_1.pdf?v=1780969466\"\u003eCJ12-22 technical datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1y9is29\" data-start=\"5540\" data-end=\"5597\"\u003eExcellence for the Australian and New Zealand Market\u003c\/h2\u003e\n\u003cp data-start=\"5598\" data-end=\"5946\"\u003eThe \u003cstrong data-start=\"5602\" data-end=\"5647\"\u003eCJ12-22 12V 22Ah sealed lead acid battery\u003c\/strong\u003e is well suited to Australian and New Zealand backup power requirements across security, fire, emergency lighting, UPS and commercial standby systems. It supports dependable performance in local operating environments when installed and maintained according to the supplied technical specifications.\u003c\/p\u003e\n\u003cp data-start=\"5948\" data-end=\"6363\"\u003eThis product should be sourced through authorised brand representatives or approved distribution channels to help ensure genuine supply, correct product support and warranty handling through direct communication with the brand or authorised supplier. The supplied specification references \u003cstrong data-start=\"6237\" data-end=\"6248\"\u003eISO9001\u003c\/strong\u003e, supporting quality-managed manufacturing processes. NDSS approval is \u003cstrong data-start=\"6319\" data-end=\"6337\"\u003enot applicable\u003c\/strong\u003e to this battery category.\u003c\/p\u003e\n\u003ch2 data-section-id=\"rg3zdl\" data-start=\"6365\" data-end=\"6378\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 data-section-id=\"6ikbom\" data-start=\"6380\" data-end=\"6423\"\u003eWhat is the CJ12-22 battery used for?\u003c\/h3\u003e\n\u003cp data-start=\"6424\" data-end=\"6596\"\u003eThe \u003cstrong data-start=\"6428\" data-end=\"6439\"\u003eCJ12-22\u003c\/strong\u003e battery is used for backup and standby power in UPS systems, fire panels, emergency lighting, security systems and other 12V electrical backup applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ew9gp9\" data-start=\"6598\" data-end=\"6638\"\u003eIs the CJ12-22 a 12V 22Ah battery?\u003c\/h3\u003e\n\u003cp data-start=\"6639\" data-end=\"6733\"\u003eYes, the \u003cstrong data-start=\"6648\" data-end=\"6659\"\u003eCJ12-22\u003c\/strong\u003e is a \u003cstrong data-start=\"6665\" data-end=\"6702\"\u003e12V 22Ah sealed lead acid battery\u003c\/strong\u003e with a 20-hour rated capacity.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lm37yv\" data-start=\"6735\" data-end=\"6777\"\u003eIs the CJ12-22 battery rechargeable?\u003c\/h3\u003e\n\u003cp data-start=\"6778\" data-end=\"6899\"\u003eYes, the \u003cstrong data-start=\"6787\" data-end=\"6798\"\u003eCJ12-22\u003c\/strong\u003e is a rechargeable sealed lead acid VRLA battery designed for standby and cycle service applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11qedgp\" data-start=\"6901\" data-end=\"6951\"\u003eWhat terminals does the CJ12-22 battery use?\u003c\/h3\u003e\n\u003cp data-start=\"6952\" data-end=\"7001\"\u003eThe \u003cstrong data-start=\"6956\" data-end=\"6967\"\u003eCJ12-22\u003c\/strong\u003e uses \u003cstrong data-start=\"6973\" data-end=\"7000\"\u003eFaston F3\/F13 terminals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1m9l9yd\" data-start=\"7003\" data-end=\"7056\"\u003eWhat are the dimensions of the CJ12-22 battery?\u003c\/h3\u003e\n\u003cp data-start=\"7057\" data-end=\"7122\"\u003eThe \u003cstrong data-start=\"7061\" data-end=\"7072\"\u003eCJ12-22\u003c\/strong\u003e measures \u003cstrong data-start=\"7082\" data-end=\"7121\"\u003e181mm long x 77mm wide x 167mm high\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17o9fsa\" data-start=\"7124\" data-end=\"7172\"\u003eWhat is the weight of the CJ12-22 battery?\u003c\/h3\u003e\n\u003cp data-start=\"7173\" data-end=\"7220\"\u003eThe \u003cstrong data-start=\"7177\" data-end=\"7188\"\u003eCJ12-22\u003c\/strong\u003e weighs approximately \u003cstrong data-start=\"7210\" data-end=\"7219\"\u003e5.9kg\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1szh3ky\" data-start=\"7222\" data-end=\"7281\"\u003eWhat is the maximum discharge current of the CJ12-22?\u003c\/h3\u003e\n\u003cp data-start=\"7282\" data-end=\"7356\"\u003eThe \u003cstrong data-start=\"7286\" data-end=\"7297\"\u003eCJ12-22\u003c\/strong\u003e has a maximum discharge current of \u003cstrong data-start=\"7333\" data-end=\"7355\"\u003e220A for 5 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hx8kig\" data-start=\"7358\" data-end=\"7415\"\u003eWhat is the float charging voltage for the CJ12-22?\u003c\/h3\u003e\n\u003cp data-start=\"7416\" data-end=\"7497\"\u003eThe \u003cstrong data-start=\"7420\" data-end=\"7431\"\u003eCJ12-22\u003c\/strong\u003e float charging voltage is \u003cstrong data-start=\"7458\" data-end=\"7496\"\u003e13.7V to 13.9V DC per unit at 25°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nfortq\" data-start=\"7499\" data-end=\"7570\"\u003eWhat is the recommended maximum charging current for the CJ12-22?\u003c\/h3\u003e\n\u003cp data-start=\"7571\" data-end=\"7642\"\u003eThe \u003cstrong data-start=\"7575\" data-end=\"7586\"\u003eCJ12-22\u003c\/strong\u003e has a recommended maximum charging current of \u003cstrong data-start=\"7633\" data-end=\"7641\"\u003e6.0A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"16qd8mu\" data-start=\"7644\" data-end=\"7713\"\u003eIs the CJ12-22 suitable for fire panels and emergency lighting?\u003c\/h3\u003e\n\u003cp data-start=\"7714\" data-end=\"7873\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eYes, the \u003cstrong data-start=\"7723\" data-end=\"7734\"\u003eCJ12-22\u003c\/strong\u003e is suitable for fire panels, emergency lighting, UPS systems and security equipment where a 12V 22Ah sealed lead acid battery is required.\u003c\/p\u003e","brand":"CCTV Tradie","offers":[{"title":"Default Title","offer_id":49693295575279,"sku":"CJ12-22-SED","price":121.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/BAT4067_product-image_1.jpg?v=1780969562","url":"https:\/\/cctvimporters.com.au\/hi\/products\/cj12-22-12v-22ah-sealed-lead-acid-battery-high-rate-vrla-agm-battery-for-ups-fire-panels-security-emergency-lighting","provider":"CCTV Tradie","version":"1.0","type":"link"}